See the OT-2 in action
Fill out this form to view our video library and learn in-depth about our OT-2 Robot.
Automated pipetting made easy. And affordable.
The OT-2 Robot is a high-performance benchtop liquid handler that meets or exceeds the accuracy of other lab robots. For under $10,000.
- Automated lab preparations and workflows
- Customizable hardware configurations and pipettes
- Compatible with existing labware and reagents
- Compact footprint with audio and video integrations
TRUSTED GLOBALLY BY OUR PARTNERS







Getting lab work done is easy with OT-2
The OT-2 lab robot is ideal for a variety of applications

Genomics

Proteomics

Cell-based assays

Biochemical assays

Drug discovery
Flexible, open-source, and user-friendly.
Highly flexible
Configure it to your requirements.
- 11-deck platform with options for Magnetic, Temperature, and Thermocycler Modules
- Swappable single and eight-channel pipettes for multiple volume options
- Standardized (SBS) deck slots work with your existing labware

Outstanding Performance
Accurate and Precise.
- Accuracy: 15% at 1µL
- Precision: 5% at 1µL
- Throughput: Fills a 96-well plate in 22 seconds

User-friendly
Intuitive, and integrates easily.
You can set up and install the OT-2 yourself. It's plug-and-play, with immediate access to protocol libraries. It easily integrates to your existing instruments and is reagent and bead system agnostic.
Choose the free protocol you prefer: beginner-friendly or advanced, with powerful cloud-based tools to gain unmatched control of your workflow.

Open source
Customizable control for maximum versatility.
- 100% customizable—you can modify according to your assay
- Use the simple, yet powerful Python AI to modify or customize protocols
- Digital protocol commands surpass manual pipetting


Watch our pre-recorded demo video series.
This 4-part series covers OT-2 product basics in detail, and
provides an overview of the Opentrons ecosystem.

Small footprint. Big impact
Only taking up half of your standard lab bench, the OT-2 robot turns complex lab work into automated workflows using high-powered technology while leaving a compact footprint. Designed for ease of use, the automated system can help you standardize routine lab preparations.
Use what you have, add what you need
No pipetting job is too big for the O2-T robot. Fitted with 11 deck slots, plus trash, and space for two, swappable pipettes, you can automate the most time-consuming applications in your lab. With fewer errors and more efficient processes, the O2-T robot can cut set-up times in half and minimize the need for intervention.

Compact footprint
- 63cm x 57cm x 66cm / 25in x 22.5in x 26in (W,D,H)
- Takes up half of your standard lab bench
Pipette configurations
- Single and 8-channel pipetting
- 2-pipette mounts, for a configuration of 1 or 2 single or 8-channel pipettes. Pipettes are easily interchangeable.
Pipette volumes and specs
- Single channel: 1-1000µl
- 8-channel: 1-300µl
- Opentrons Pipette Whitepaper (GEN1 & GEN2) ›
- Single channel manual ›
- 8-channel manual ›
Deck
- 11 deck slots enable countless configurations
- Deck slots are compatible with standard SBS dimensions. Deck also includes a removable trash bin.
Connectivity
- WiFi 2.4 GHz IEEE 802.11b/g/n, USB 2.0
- Learn more ›
Weight
- 48kg or 105.8 lb
Video
- Integrated video camera (Included for future or custom functionality)
Audio
- Integrated audio system (Included for future or custom functionality)
Power Requirements
- Robot Power Input: 36VDC, 6.1A
- Power Adapter Input: 100-240VAC, 50/60Hz, 4.0A/115VAC, 2.0A/230VAC
- For additional power requirement information, please review this support article
Frame composition
- Rigid steel and CNC aluminum design
Operating Temperature & Relative Humidity
- Recommended 20-24C Recommended 40-60% RH
- Learn more ›
Speed
Fills a 96-well plate in 22 seconds
Pipette | Distribute, One Tip |
Transfer, Same Tip |
Transfer, New Tip |
---|---|---|---|
P20
8-channel
|
0:22 | 1:35 | 4:19 |
P300
8-channel
|
0:26 | 1:38 | 4:24 |
P20 Single
|
3:12 | 13:10 | 36:01 |
P300 Single
|
4:01 | 13:39 | 41:31 |
P1000 Single
|
5:54 | 15:21 | 44:50 |
Accuracy and precision
Single and 8-channel pipetting
Pipette | Volume | Random Error | Systematic Error | ||
---|---|---|---|---|---|
%D | µl | %CV | µl | ||
p20 | 1 | ±15% | 0.15µL | ±5% | 0.05µL |
10 | ±2% | 0.2µL | ±1% | 0.1µL | |
20 | ±1.5% | 0.3µL | ±0.8% | 0.16µL | |
p300 | 20 | ±4% | 0.8µL | ±2.5% | 0.5µL |
150 | ±1% | 1.5µL | ±0.4% | 0.6µL | |
300 | ±0.6% | 1.8µL | ±0.3% | 0.9µL | |
p1000 | 100 | ±2% | 2.0µL | ±1% | 1µL |
500 | ±1% | 5.0µL | ±0.2% | 1µL | |
1000 | ±0.7% | 7.0µL | ±0.15% | 1.5µL |
Pipette | Volume | Random Error | Systematic Error | ||
---|---|---|---|---|---|
%D | µl | %CV | µl | ||
P20 | 1 | ±20% | 0.2µL | ±10% | 0.1µL |
10 | ±3% | 0.3µL | ±2% | 0.2µL | |
20 | ± 2.2% | 0.44µL | ±1.5% | 0.3µL | |
P300 | 20 | ±10% | 2.0µL | ±4% | 0.8µL |
150 | ±2.5% | 3.75µL | ±0.8% | 1.2µL | |
300 | ±1.5% | 4.5µL | ±0.5% | 1.5µL |
Sterility
Full polycarbonate enclosure designed to limit exposure. The OT-2 is not a sterile environment
Add the Opentrons HEPA Module, or add your own UV lights
Viscosity
For best practices on automating viscous liquid handling, review our application note
API compatibility
- Interfaces with any product that has an API
- Opentrons software is open-source and users can make adjustments to the software as needed to interface with other products. While all integrations are possible, they all require custom code work i.e. most customers will need to write custom libraries and install software packages that are not shipped with the robot.
- Learn more ›
Interface
- Windows 10, macOS 10.10 or later, Ubuntu 12.04 or later.
- Opentrons App ›
Tip compatibility
- Use Opentrons Tips and Opentrons Filter Tips
- Opentrons guarantees the performance of Opentrons Tips which were specifically designed for the OT-2. The OT-2 was designed to accommodate all universal bore tip types, but tip quality and dimensions can vary significantly so third party tip performance cannot be guaranteed by Opentrons.
Labware compatibility
- Use common labware already in our Labware Library, or add your own
- If your labware fits on the OT-2 but is not in the Labware Library, it can be added by you using our Labware Creator, or by our team.
- Learn more ›
- OT-2 Manual ›
Warranty
- One year warranty against manufacturer defects
- Stress tested to last a minimum of 3 years of full-time use
- Learn more ›
Return Policy
- 60 day, 100% risk free
- Learn more ›
Certifications
- Certifications complete (CE, FCC, NRTL, CB, ISO 9001)
- Not certified/validated (IVD, GMP)
Tip Handling
- Pick up tip
- Drop tip
- Return tip
- New tip (always, never, once)
- More...
Liquid Control
- Aspirate
- Dispense
- Aspirate speed
- Dispense speed
- Blowout
- Touch tip
- Mix
- Air gap
Utility
- Move to
- Delay
- User-specified pause
- Homing
- Comment
Transfer
- Basic transfer
- Volumes > Pipette Volume
- Distribute
- Consolidate
Variable Settings
- Speed
- Volume
- Count
Other
- Dispose
-
Compact footprint
- 63cm x 57cm x 66cm / 25in x 22.5in x 26in (W,D,H)
- Takes up half of your standard lab bench
Pipette configurations
- Single and 8-channel pipetting
- 2-pipette mounts, for a configuration of 1 or 2 single or 8-channel pipettes. Pipettes are easily interchangeable.
Pipette volumes and specs
- Single channel: 1-1000µl
- 8-channel: 1-300µl
- Opentrons Pipette Whitepaper (GEN1 & GEN2) ›
- Single channel manual ›
- 8-channel manual ›
Deck
- 11 deck slots enable countless configurations
- Deck slots are compatible with standard SBS dimensions. Deck also includes a removable trash bin.
Connectivity
- WiFi 2.4 GHz IEEE 802.11b/g/n, USB 2.0
- Learn more ›
Weight
- 48kg or 105.8 lb
Video
- Integrated video camera (Included for future or custom functionality)
Audio
- Integrated audio system (Included for future or custom functionality)
Power Requirements
- Robot Power Input: 36VDC, 6.1A
- Power Adapter Input: 100-240VAC, 50/60Hz, 4.0A/115VAC, 2.0A/230VAC
- For additional power requirement information, please review this support article
Frame composition
- Rigid steel and CNC aluminum design
Operating Temperature & Relative Humidity
- Recommended 20-24C Recommended 40-60% RH
- Learn more ›
-
Speed
Fills a 96-well plate in 22 seconds
Time to fill 96-well plate Pipette Distribute,
One TipTransfer,
Same TipTransfer,
New TipP208-channel0:22 1:35 4:19 P3008-channel0:26 1:38 4:24 P20 Single3:12 13:10 36:01 P300 Single4:01 13:39 41:31 P1000 Single5:54 15:21 44:50
Accuracy and precision
Single and 8-channel pipetting
Single Channel Accuracy & Precision Pipette Volume Random Error Systematic Error %D µl %CV µl p20 1 ±15% 0.15µL ±5% 0.05µL 10 ±2% 0.2µL ±1% 0.1µL 20 ±1.5% 0.3µL ±0.8% 0.16µL p300 20 ±4% 0.8µL ±2.5% 0.5µL 150 ±1% 1.5µL ±0.4% 0.6µL 300 ±0.6% 1.8µL ±0.3% 0.9µL p1000 100 ±2% 2.0µL ±1% 1µL 500 ±1% 5.0µL ±0.2% 1µL 1000 ±0.7% 7.0µL ±0.15% 1.5µL 8-Channel Accuracy & Precision Pipette Volume Random Error Systematic Error %D µl %CV µl P20 1 ±20% 0.2µL ±10% 0.1µL 10 ±3% 0.3µL ±2% 0.2µL 20 ± 2.2% 0.44µL ±1.5% 0.3µL P300 20 ±10% 2.0µL ±4% 0.8µL 150 ±2.5% 3.75µL ±0.8% 1.2µL 300 ±1.5% 4.5µL ±0.5% 1.5µL
Sterility
Full polycarbonate enclosure designed to limit exposure. The OT-2 is not a sterile environment
Add the Opentrons HEPA Module, or add your own UV lights
Viscosity
For best practices on automating viscous liquid handling, review our application note
-
API compatibility
- Interfaces with any product that has an API
- Opentrons software is open-source and users can make adjustments to the software as needed to interface with other products. While all integrations are possible, they all require custom code work i.e. most customers will need to write custom libraries and install software packages that are not shipped with the robot.
- Learn more ›
Interface
- Windows 10, macOS 10.10 or later, Ubuntu 12.04 or later.
- Opentrons App ›
Tip compatibility
- Use Opentrons Tips and Opentrons Filter Tips
- Opentrons guarantees the performance of Opentrons Tips which were specifically designed for the OT-2. The OT-2 was designed to accommodate all universal bore tip types, but tip quality and dimensions can vary significantly so third party tip performance cannot be guaranteed by Opentrons.
Labware compatibility
- Use common labware already in our Labware Library, or add your own
- If your labware fits on the OT-2 but is not in the Labware Library, it can be added by you using our Labware Creator, or by our team.
- Learn more ›
- OT-2 Manual ›
-
Warranty
- One year warranty against manufacturer defects
- Stress tested to last a minimum of 3 years of full-time use
- Learn more ›
Return Policy
- 60 day, 100% risk free
- Learn more ›
Certifications
- Certifications complete (CE, FCC, NRTL, CB, ISO 9001)
- Not certified/validated (IVD, GMP)
-
Tip Handling
- Pick up tip
- Drop tip
- Return tip
- New tip (always, never, once)
- More...
Liquid Control
- Aspirate
- Dispense
- Aspirate speed
- Dispense speed
- Blowout
- Touch tip
- Mix
- Air gap
Utility
- Move to
- Delay
- User-specified pause
- Homing
- Comment
Transfer
- Basic transfer
- Volumes > Pipette Volume
- Distribute
- Consolidate
Variable Settings
- Speed
- Volume
- Count
Other
- Dispose
Watch our pre-recorded demo video series.
This 4-part series covers OT-2 product basics in detail, and provides an overview of the Opentrons ecosystem.